To Build a Schematic Representation

To build a schematic representation

  1. In the Maintenance workspace, open an industry model drawing or an enterprise industry model project.
  2. Click Home tab > Data Source panel.
  3. From the Representation list, select the schema to work on.
  4. In the Workflow explorer, right-click Build Schematic. Click Execute.
  5. Do one of the following:
    • Click Select In Map. Select the features to include in the schematic.

      The selected features populate the schematic Feature Explorer in the Review And Modify Selection area.

    • Click Select From Trace. Define a network trace and click OK.

      The traced features populate the schematic Feature explorer in the Review And Modify Selection area.

      You can select a stop condition through the schematics Select From Trace workflow. You cannot edit an existing stop condition, but you can define a new one through the schematics workflow . The new stop condition is saved to the database. You can edit the new stop condition.

      The trace direction is initially set by the direction value in the tracing template. You can override the direction through the schematics workflow. This value is then stored in TB_SETTINGS. When you use the trace template through the schematics workflow, the TB_SETTINGS value is applied. The direction value in the trace template stored in the database is not changed.

    • Use Feature Specific Selection to navigate the industry model tree and display forms for the feature classes to include in the trace. Select features by attribute, or include all features in the feature class. Click Add The Features In This Dialog To The Schematics Workflow Feature Explorer.

      The selected features are added to the schematic workflow Feature explorer. Only features that are included in the schema topology are shown in the industry model tree. The selected features populate the schematic Feature Explorer in the Review And Modify Selection area.

  6. Review the set of features in the schematic Feature explorer. Clear any features to exclude from the schematic.
  7. Click Build to generate the schematic.

    Only features that are included in the schema topology are included in the schematic. The schematic Feature explorer displays the remaining features.

    Note:

    To add new features to the schematic, run the Build Schematic workflow again and include just the new features.