To Find Feeders

Use the Find Feeders workflow to find the breaker or transformer that feeds the selected feature. The workflow is designed to trace from the consumer to the electricity source.

  1. Click Home tab Display panel Generate Graphic.
  2. Click the Workflow Explorer icon to display the workflows.
  3. Under Client Workflows, Analysis workflows, click Find Feeders. Click Execute.
  4. Click Select Start Feature. Select the start feature (device or conductor) in the map.
  5. Click Select Stop Feature. Select one or more stop features in the map.
    Note:

    Tracing a network without stop features can take a very long time.

  6. Under Stop Condition: Feeder Type, select the Stop Condition feature classes or click All.
  7. Click OK to run the workflow.

    When the workflow has finished, the feeders are highlighted in the map and listed in a tree view in the Workflows pane. Use the tools at the top of the Workflows pane to open the feature class form, highlight selected features, and zoom to selected features.

  8. Enter REGEN on the command line to clear the selection in the map.