Thermocouple controlled cooling Thermocouple dialog

To access this dialog, open the Thermocouple controlled cooling inlet dialog, select Thermocouple for the Valve control method and click Specify.

Property Description
Thermocouple control All the items in this section refer to a node in the mold close to where the actual thermocouple is located in the mold. The temperature of this node is monitored during the simulation and is used to control the flow in the circuit on which the boundary condition has been applied.
Switch off temperature Enter the temperature at which the flow control valve should be turned off.
Minimum off time Enter a time, in seconds, to delay switching off the flow control valve.
Switch on temperature Enter the temperature at which the flow control valve should be turned on.
Minimum on time Enter a time, in seconds, to delay switching on the flow control valve.
Thermocouple node Specify whether the node where thermocouple is located.