Tasks to set up a wall slip analysis

To set up a wall slip analysis, either follow the order of the buttons on the Home tab of the ribbon UI, or follow the order of the items in the Study Tasks pane. Make sure you have a 3D model, and that you select an analysis sequence that includes Fill.

Note: There are some recommendations for you to consider when setting up a wall slip analysis, to ensure you maximize the effect:

When you get to the process settings, to enable a wall slip analysis:

  1. In the Process Settings Wizard dialog, click Next if necessary until you find the Advanced options button.
  2. Click Advanced options.
  3. Click Edit associated with the Solver parameters.
  4. In the Fill + Pack Analysis tab, ensure that Simulate wall slip is set to Yes, then click Edit wall slip parameters and enter your material data.
  5. Check the Simulate inertia effect option to enhance jetting.
  6. Click Filling parameters, and change the Maximum %volume to fill per time step to 1% instead of using the default 4%.

When all the items in the Study Tasks pane have check marks against them, the analysis is ready to launch.

Setup task Analysis technology
Select the Molding process
Mesh the model
Check the mesh before analysis
Select an analysis sequence that includes Fill
Select a material that you have had characterized for wall slip analyses
Set an injection location
Set the velocity/pressure switchover point
Enter the process settings
Enable the wall slip analysis