Message text
** ERROR 313395 ** Rotational components are present in the mold model. Different rotational reference points are specified for different components. All rotational components in the model must have the same rotational reference point. Ensure that rotational components in the model have the same reference point.
Explanation
This error is fatal. The rotational reference point must be unique. At least two different reference points have been set for mold components in the study.
Resolution
- Select a first rotational component.
- Right-click in the Model pane and select Properties. Select Mold block (3D) and click
OK.
- Select the Overmolding Mold Component
tab.
- Click
Set.. it and note the coordinates of reference point.
- Repeat all these steps with every rotational mold part and notice the inconsistency.
- Change the coordinates of the inconsistent
Reference point.
- Click
OK in the
Mold block (3D) dialog.
Note: Before clicking
OK, ensure that the box
Apply to all entities that share this property is deselected if both mold components have the same
Mold block (3D) property.