Message Text
** ERROR 320004 ** Master barrel cannot refer to itself when injection delay is 'by ram position'.
Explanation
In the
Delay timer dialog, you have entered the node ID of the master barrel injection location as the
Reference injection node. The master barrel cannot delay its start relative to itself.
Resolution
Enter the node ID of the sub barrel injection location relative to which you want to delay the master barrel injection start.
- Identify the sub barrel relative to which you want to delay the master barrel injection.
- In the
Layers panel, make visible the mesh nodes layer.
- Zoom in on the node to which the sub-barrel is attached, and select the node so that it changes color.
- Open the
Geometry tab and copy the node ID from the
Selection panel. The node ID is a number that is preceded by the letter N.
- Click
() to open the
Process Settings Wizard.
- Click
Set associated with the
Delay timer, to open the timer dialog.
- Paste the node ID against the
Reference injection node.
- Click
OK twice to close the dialogs, and start the analysis again.