Message Text
** WARNING 301744 ** The temperature dependency needs to be characterized by rheology testing for wall slip. Wall slip analysis with temperature dependency included may encounter convergence difficulty.
Explanation
The use of temperature dependency (
)is not recommended, unless you have characterized your own material, as no reliable data are available at this point.
Resolution
Change the temperature dependency value to zero, or check your material data to ensure the value you have entered is correct. To do this:
- Click
(.
- In the
Process Settings Wizard dialog, click
Next if necessary until you find the
Advanced options button.
- Click
Advanced options.
- Click
Edit associated with the
Solver parameters.
- Click
Edit wall slip parameters, and enter zero (0) for the temperature dependency (
).