| E5107
|
FATAL ERROR: E5107
|
ONE OR MORE FATIGUE PARAMETERS ARE ZERO OR UNDEFINED, STATUS:
n
|
|
|
Cause:
|
A zero fatigue parameter value was detected when a non-zero value was required in a multiaxial or vibration fatigue analysis. The status codes have the following meaning:
| Code
|
Meaning
|
| 1
|
S-N curve slope (B) is zero.
|
| 2
|
Intercept stress level (SU) is zero.
|
| 3
|
Coefficient of fatigue strength (SF) is zero.
|
| 4
|
Coefficient of fatigue ductility (EF) is zero.
|
| 5
|
Exponent of fatigue strength (B) is zero.
|
| 6
|
Exponent of fatigue ductility (C) is zero.
|
|
|
|
Action:
|
Correct the input data on the corresponding FATIGUE, VFATIGUE, SNDATA, or ENDATA Bulk Data entry based on the status code.
|
|
|
Remarks:
|
See Autodesk Nastran Reference Guide, Section 4,
Bulk Data, for
FATIGUE,
VFATIGUE,
SNDATA, and
ENDATA entry formats.
|