| E5050 | WARNING: E5050 | EXCESSIVE MATRIX FACTOR DIAGONAL RATIO(S) DETECTED |
| Cause: | One or more stiffness matrix factor diagonal ratios was greater than the parameter FACTRATIOTOL/MAXRATIO (default 1.0E+5). During stiffness matrix factorization (decomposition), for each degree of freedom, the ratio of stiffness to factored stiffness is calculated. A value greater than 1.0E+5 indicates a possible mechanism at that degree of freedom. | |
| Action: | Investigate the degree(s) of freedom at which the large ratio occurred. | |
| Remarks: | None. |