There are several ways to apply a slope to piping:
Use the slope options on the ribbon to specify the slope as you draw horizontal pipe in a view. This method is typically used to specify small slopes.
Floor Plans and double-click a view for the piping system.
Plumbing & Piping panel
Placement Tools panel, select placement options. | If you want to ... | then ... |
|---|---|
| change the orientation of the tag | select Horizontal or Vertical. |
| load additional tags | click Tags. |
| include a leader line between the tag and the pipe | select Leader. |
| change the default length of the leader | enter a value in the text box to the right of the Leader check box. |
Sloped Piping panel, click
Slope Up or
Slope Down, and select a Slope Value from the drop-list.
Show Slope Tooltip. The starting point is also the reference end for the slope that is applied. When a positive slope is specified, the reference end is lower than the endpoint. Specifying a negative slope places the endpoint below the reference end (starting point).
The sloped pipe is added in the drawing area.
Modify the elevation controls that display when a pipe segment is selected in the view to apply a small slope to non-sloped pipe.

Slope value and reference controls are added at the midpoint of the pipe segment. The slope reference control points toward the reference end for the slope, which is the start point that was used when the original pipe was drawn. The reference end remains at its current elevation when the value for the slope is changed.

Toggle the reference end
Modify the controls that display when a pipe segment is selected in the view to adjust an existing slope.
The slope control points toward the reference end for the slope, which is the start point that was used when the original pipe was drawn.
The reference end remains at its current elevation when the value for the slope is changed.
To connect to an existing pipe with a different elevation, you can connect using the current slope value or ignore the slope value to connect directly.
Offset Connection tab
Change Slope.
Offset Connection tab
Add Vertical. The pipe is directly connected, regardless of the current slope value.