To place hangers, select a service and a group.
Video: Working with Hangers in a Fabrication Model in Revit
Use the MEP Fabrication Parts palette to select a service and a group, and select a fabrication hanger to place in the drawing area. If no parts are listed in the palette, click Settings to open the Fabrication Settings dialog and load content into the MEP Fabrication Parts palette.
You can place hangers on straight horizontal fabrication segments or on straight portions of fitting extensions. You can also place hangers on a sloped host.
Hangers can also be placed in free space and not connected to a fabrication part. Adjust the rod length to attach a bearer hanger to the structure of another bearer hanger.
Fabrication panel
(Fabrication Part)
Windows panel
MEP Fabrication Parts
MEP Fabrication Parts
By default, hangers are attached to the closest structure element. Structure categories include floor, roof, structure framing (such as beam or truss), stairs, and slabs. If no structure is available, Revit uses the default rod length as set in the ITM file definition.
Check Systems panel
(Show Disconnects) and select one or more of the following: