On certain MEP fabrication ductwork parts, you can add, remove, or rotate integral damper blades using in-canvas controls that are specific to dampers.
For example, it is possible to add integral damper blades on round HVAC fabrication parts, including square to round transitions. You can also select a specific type of damper from a drop-down list, and add, rotate, or remove it.
Only MEP fabrication ductwork parts that can accommodate integral dampers have this functionality; for example, straights, tees, taps, reducers, square to round transitions, and some types of equipment.
Video: Add Dampers to MEP Fabrication Parts
To add a damper
When you select a part that can have an integral damper added to it, the Add Damper control displays.
Add Damper.
Rotates the damper shaft counter-clockwise around the connector.
Removes the current damper.
Rotates the damper shaft clockwise around the connector.
Damper Type: When a damper is added and selected, the damper type name displays as text above the damper controls, as shown below. In this example, the damper type name is “Round Damper”.
When you do this, the Change Damper Type drop-down control displays, as shown below.
Specifications
Dampers section of the database. For more information, see Dampers in the Autodesk Fabrication product Help.
Click this control to display a drop-down list of available damper types for the currently selected part, as shown below.
To remove a damper
Remove Damper.
To rotate a damper
Use the rotate tools to set the damper handle location.
or clockwise
in relation to the connector. Round dampers rotate in 45-degree increments, while rectangular ones rotate at 90-degree increments.