Use this dialog box to view and change pressure network-related settings.
This topic documents settings in the pressure network Edit Settings dialog boxes (feature settings and command settings).
- Feature settings inherited from the drawing ambient settings are identified by the drawing icon in the dialog boxes. For more information about these settings, see Ambient Settings Tab (Drawing Settings Dialog Box).
- Feature settings for pressure networks are identified by the pressure network icon.
- Command settings for specific pressure network commands are identified by the command icon.
For more information about this dialog box, see About Autodesk Civil 3D Settings.
Default Styles
Use these settings to establish the default styles assigned to pressure network components. For each of these items, click in the Value column, and click to select the style or parts list.
-
Appurtenance Default Style
-
Specifies the default style for appurtenances in pressure networks.
-
Fitting Default Style
-
Specifies the default style for fittings in pressure networks.
-
Pressure Pipe Default Style
-
Specifies the default style for pipes in pressure networks.
-
Fitting Plan Label Style
-
Specifies the label style used for fittings inserted into the pressure network in plan view.
-
Appurtenance Plan Label Style
-
Specifies the label style used for appurtenances inserted into the pressure network in plan view.
-
Pressure Pipe Plan Label Style
-
Specifies the label style used for pipes inserted into the pressure network in plan view.
-
Fitting Profile Label Style
-
Specifies the label style used to display the fittings within the pressure network in a profile view.
-
Default Parts List
-
Specifies the default parts list for pressure networks.
-
Appurtenance Profile Label Style
-
Specifies the label style used to display the appurtenances within the pressure network in a profile view.
-
Pressure Pipe Profile Label Style
-
Specifies the label style used to display the pipes within the pressure network in a profile view.
-
Crossing Pressure Pipe Profile Label Style
-
Specifies the default style for crossing pressure pipe labels that are displayed in profile view.
-
Crossing Pressure Pipe Section Label Style
-
Specifies the default style for crossing pressure pipe labels that are displayed in section view.
-
Render Material
-
Specifies the default render material for pressure networks.
Default Name Format
Use these settings to specify the default name formats for pressure network components. Click in the Value column, and click to make changes in the Name Template dialog box.
Default Profile Label Placement
Use these settings to establish the default placement of profile view labels associated with the pressure network. You can specify the following settings for pressure pipes, fittings, and appurtenances:
- Dimension Anchor Option
-
Specifies the location of the dimension line anchor for profile view labels for pressure networks:
- Fixed: Places the dimension line anchor at a fixed elevation on a profile view. Specify the elevation in the Dimension Anchor Elevation Value field.
- Above: Moves the dimension line anchor up the distance specified in the Dimension Anchor Elevation Value.
- Below: Moves the dimension line anchor down the distance specified in the Dimension Anchor Elevation Value.
- Graph View Top: Places the line anchor at the top of the profile view grid.
- Graph View Bottom: Places the line anchor at the bottom of the profile view grid.
Note: These settings impact the label location when the Anchor Point setting in the label style is set to Pipe Dimension, Fitting Dimension, or Appurtenance Dimension.
- Dimension Anchor Elevation Value
-
Specifies the elevation value to apply in relation to the specified Dimension Anchor Option. This value is used when Fixed, Above, or Below is specified as the Dimension Anchor Option for profile labels. Enter an elevation in the Value column or click and select a value in the drawing area.
Default Section Label Placement
Use these settings to establish the default placement of section view labels associated with the pressure network. You can specify the following settings for pressure pipes:
-
Dimension Anchor Option for Pressure Pipes
-
Specifies the location of the dimension line anchor for section view labels for pressure networks:
- Fixed: Places the dimension line anchor at a fixed elevation on a section view. Specify the elevation in the Dimension Anchor Elevation Value field.
- Above: Moves the dimension line anchor up the distance specified in the Dimension Anchor Plot Height Value.
- Below: Moves the dimension line anchor down the distance specified in the Dimension Anchor Plot Height Value.
- Graph View Top: Places the line anchor at the top of the section view grid.
- Graph View Bottom: Places the line anchor at the bottom of the section view grid.
Note: These settings impact the label location when the Anchor Point setting in the label style is set to Pipe Dimension.
-
Dimension Anchor Elevation Value for Pressure Pipes
-
Specifies the elevation value to apply. This value is used when Fixed is specified for the Dimension Anchor Option for Pressure Pipes for section view labels. Enter an elevation in the Value column or click and select a value in the drawing area.
-
Dimension Anchor Plot Height Value for Pressure Pipes
- Specifies the default plot height of the dimension line anchor for section view labels for pressure pipes. Enter a height in the Value column. This value is used when Above or Below is specified as the Dimension Anchor Option for Pressure Pipes for section view labels.
-
Pressure Pipe Section Label Placement
-
Specifies the default location of pressure pipe labels displayed in section views:
-
At Top Of Pipe
-
At Middle Of Pipe
-
At Bottom Of Pipe
Alignment Type Option
Note: This property group is displayed when accessing the settings for the CreateAlignFromPressureNW command.
-
Alignment Type
- Specifies the default alignment type created when using the Create Alignment From Pressure Network command.
Run Depth Check
Note: This property group is displayed when accessing the settings for the
RunDepthCheck
command.
-
Use Min Depth Of Cover Validation
- Specifies that the Minimum Depth Of Cover parameter is selected by default for the Run Depth Check command.
-
Minimum Depth Of Cover
- Specifies the default minimum depth of cover to check for when using the Run Depth Check command.
-
Use Max Depth Of Cover Validation
- Specifies that the Maximum Depth Of Cover parameter is selected by default for the Run Depth Check command.
-
Maximum Depth Of Cover
- Specifies the default maximum depth of cover to check for when using the Run Depth Check command.
Run Design Check
Note: This property group is displayed when accessing the settings for the
RunDesignCheck
command.
-
Use Deflection Validation
- Specifies that the Deflection parameter is selected by default for the Run Design Check command.
-
Use Diameter Validation
- Specifies that the Diameter parameter is selected by default for the Run Design Check command.
-
Use Open Connection Validation
- Specifies that the Open Connections parameter is selected by default for the Run Design Check command.
-
Use Radius Of Curvature Validation
- Specifies that the Radius Of Curvature parameter is selected by default for the Run Design Check command.
Table Creation
Note: This property group is displayed when accessing the settings from the AddPressurePipeTable, AddFittingTable, and AddAppurtTable commands.
Use these settings to establish the defaults when you add a pressure network pipe, fitting, or appurtenance table.
-
Table Style
-
Specifies the style for a table. Click in the Value column, and click to select a style in the Table Style dialog box.
-
Split Table
-
Specifies whether a table is split into two or more sections after a specified maximum number of rows has been met.
-
Maximum Number of Rows
-
Specifies the maximum number of rows to include per section. If the number of data rows exceeds the specified maximum, the table is split into sections, and they are displayed either side by side (left to right), or stacked vertically.
-
Maximum Tables Per Stack
-
Specifies the maximum number of sections to include in each stack.
-
Table Spacing
-
Specifies the spacing between tables.
-
Tile Direction
-
Specifies the direction in which the table tiles (across or down).