Select the Analysis Type, and optionally, advanced settings for relaxation.

Analysis type - Users can perform a thermal only analysis or a full thermo-mechanical analysis
Relaxation iterations and Relaxation scaling factors - These options are used to control the under relaxation of the Newton-Raphson solver during PRM generation. By default, the values for iterations and scaling factor are different for thermal and mechanical simulations; if you set values here in the Solver Settings dialog, they will apply to both types of simulations, overriding the defaults.
Time-Step Increment Factor: This controls the time step during processing, which based upon the laser or electron beam radius and travel speed. A value of 1 creates time steps equal to the time it takes to move 1 heat source radius. Using values lower than 1 may aid convergence or increase model resolution. In most cases, using values higher than 1 will produce aliasing in the simulation and will produce invalid results.