Customize the type parameters for a system type, including graphical overrides, materials, calculations, abbreviation, and rise/drop symbols. You can customize parameters for the default system types (supply, return, and exhaust air), as well as any new system types you create.
Video: Create a Custom System Type
Edit graphical overrides
You can customize graphical overrides to control the color, line weight, and line pattern for the collection of objects assigned to a system of that type. The graphical overrides apply to the project, and are not view-specific like filters.
Graphical overrides for a system are prioritized between Phasing and Filters. Weight, color, and line pattern per system type will override the settings per category. However, a view filter always takes precedence over the settings in the system graphical overrides.
Object Style | V/G Category Override | System | Phase | View Filter | Instance | |
---|---|---|---|---|---|---|
Instance | ||||||
View Filter | ||||||
Phase | ||||||
System | ||||||
V/G Category Override | ||||||
Object Style |
Edit other system parameters
You can edit the materials, calculations, abbreviation, and rise/drop symbols for a system.
Enable performance mode for duct and piping systems
Use the Performance mode to improve Revit's performance when editing large MEP system networks.
System propagation is disabled on every system in the project that uses that system type. All other systems will remain as before.
Calculations Setting | |||||
---|---|---|---|---|---|
System Classification | All | Flow Only | Volume Only | None | Performance |
Supply Air | |||||
Return Air | |||||
Exhaust Air | |||||
Domestic Cold Water | |||||
Domestic Hot Water | |||||
Hydronic Supply | |||||
Hydronic Return | |||||
Sanitary | |||||
Vent | |||||
Other | |||||
Fire Protection Wet | |||||
Fire Protection Dry | |||||
Fire Protection Pre-Action | |||||
Fire Protection Other |