Fixed Issues

Autodesk Trust Center

For the latest information regarding security fixes in this update, refer to these Security Advisories:

Problems Reported Through the Customer Error Reporting Utility

As a result of the detailed information that we received from customers who used the Customer Error Reporting Utility, we were able to identify and fix several defects including the following:

2021.1.3 Update

Collaboration Workflow
Occasional crashes when adding a drawing, or copying components in a project with large amounts of referenced drawings.

2021.1.1 Update

Piping
Occasional crashes when reopening projects from the Project Manager.
Occasional crashes when creating a custom part for reducers.

2021.1 Update

Collaboration Workflow
Fixed an issue where project refresh may cause a crash.
Fixed an issue where files check-in may cause a crash.

2021.0.1 Update

Orthographics
Fixed an issue where parallel ortho generation may cause a crash.


General Update Content

The following defects have been fixed:

2021.1.3 Update

Data Manager
Improved performance when refreshing the Data Manager.
P&ID
The application no longer freezes when using the STRETCH command.

2021.1.2 Update

Vault Workflow
The PLANTAUDITVAULTPROJECT command now corrects errors as expected.
P&ID
Some missing slines now display in the project database and can be connected to an OPC.
Piping
Multi-port valve correctly displays after modifying the angle values.
Slope pipe routing now works as expected.
Isometrics
Pipe now displays in BOM when a reducer connects to a pulled pipe for two different line numbers.
Spec Editor
The spec is now updated with the changes of valves in the catalog when defining the piping component as valve.
Report Creator
Pipeline segments no longer display multiple times in Report Creator.

2021.1.1 Update

Collaboration Workflow
Check-ins are now successful when using the same template (DWT) in multiple locations.
Irrelevant iso drawings are no longer downloaded automatically when creating iso for some pipe lines.
Duplicated drawings no longer display in Project Manager when two different users check in different drawings with same naming at the same time.
“Number of inbound relationships exceeds the limit” message no longer displays when checking in drawings.
Project drawings with Naming Standard applied can now be removed.
Vault Workflow
"Subscribe to Autodesk BIM Collaborate Pro" message no longer shows when opening Vault projects.
Project Settings
Boolean properties can now be changed in the Properties Palette.
The Boolean custom attribute checkbox now displays in Data Manager.
P&ID
Child class now inherits the display name of the parent class.
Reducer sizes are updated correctly after changing the size of a pipe line.
Reducer sizes are updated correctly after reversing the flow of a pipe line.
Sline no longer disappears when P&ID painter is turned on with color fading settings.
The "from" property is now updated for the new pipe lines.
Piping
Pipe routing now uses the correct UCS settings.
Substituting gasket no longer breaks the flange connections.
Substituting gasket now adjusts the pipe length accordingly.
Isometrics
The size of imperial bolt sets no longer shows as decimal in BOM.
Orthographics
Annotation leader line is now placed correctly according to the text location.
Column width and row height in the BOM table no longer reset when the ortho view is updated.
Referenced Advance Steel drawings can now display correctly in Ortho drawings.
Referenced Civil 3D drawings can now display correctly in Ortho drawings.

2021.1 Update

Collaboration Workflow
Collaboration projects now support the new Autodesk Constructruction Cloud.
Data center location now displays only in the Project Details pane of the Project Manager.
Fixed an issue where duplicate files are created in the cloud database in certain conditions.
Fixed an issue where a duplicate tag name can be checked in.
Unsupported characters for a folder name are removed when creating a new folder.
Improved performance when refreshing multiple files.
Project Manager now reports the correct drawing count.
Vault Workflow
Automatic login to Vault option now works correctly.
File thumbnail is now updated by the revision change.
Fixed an issue where the PLANTAUDITVAULTPROJECT command does not correct some errors.
Improved performance when checking out multiple files.
Project Settings
Drawing Properties dialog box now displays correctly with high PPI.
Fixed an issue where layer and color settings may cause a JIT error.
The type for file name fields can now be updated.
P&ID
Acquisition properties can now be passed to pipe line segment with OPC.
Improved performance for copying control valves.
Piping
Bolt set symbol now displays with the correct scale.
The Create Equipment dialog box correctly displays when the default tag format contains custom drawing properties.
Fixed an issue where the Data Manager shows empty areas with the count of spec files.
PLANTCONTENTBLOCKUNITSMATCH system variable controls whether the unit from a block is used to scale the content block when placed into a project with a different unit.
Isometrics
Fixed an issue where one of the stub-in continuation symbols does not display when connecting to two isometric sheets.
PCF file now includes COMPONENT-ATTRIBUTE for dummy leg.
Offline instrument theme now works correctly.
Orthographics
Fixed an issue where views with cut pipe symbol are enlarged unexpectedly after editing.
Report Creator
Fixed an issue where palettes become unusable when docked in a tabbed document.

2021.0.1 Update

Collaboration Workflow
Occasional failure when sharing large projects.
Occasional failure when importing to Data Manager while signed in as a different user in a collaboration project.
DBNull error fix for some instances.
Folder properties in a collaboration project can now be updated.
The export and import settings in the Project Setup for 3D models in a collaboration project can now be updated.
Vault Workflow
P&ID tag displayed as a question mark after replacing the class and checking in.
Occasional failure when importing to Data Manager while signed in as a different user in a vault project.
Folder properties in a vault project can now be updated.
P&ID
Fixed an issue where P&ID assets switched to offline mode after reversing the flow.
Fixed an issue where P&ID instrumentation symbols are rotated after EXPORTTOAUTOCAD.
The order of assets in P&ID Line List is now based on the direction of the flow, that is from upstream to downstream.
Occasional crashes during window selection on P&ID drawings.
P&ID symbol blocks can now be changed in Project Setup.
P&ID symbol color can now be changed in Project Setup.
Piping
Fixed an issue where the weld was incorrectly placed for stub lapped joint.
Fixed an issue where the Required Properties Matches are cleared when changing Matching Values in the Pipe Connection Settings dialog box.
Fixed an issue where the adjacent pipe was deleted after placing a flange when setting Large OffsetTolerance in DefaultConnectorsConfig.xml.
Newly added equipment nozzle can keep the nozzle tag naming rule without delimiter.
Customized properties created using PLANTDEFINECALCPROPERTIES with a space in the name are now displayed with values in property palettes.
Inserting an imperial content into 3D model of metric or mixed metric project can now generate correct dimensions.
Olets can now be created in 3D model when using PLANTPCFTOPIPE for certain conditions.
Elbows can now be created correctly in 3D model when using PLANTPCFTOPIPE from PCFs even with missing elbow angle value.
Isometrics
Fixed an issue where single PCFs with a comma in the coordinates may cause PLANTPCFTOISO to fail.
Length in the cut piece list and quantity in the BOM are now shown correctly when the branch and header pipes are of the same size.
Continuous annotations are now shown in some isometric drawings.
Orthographics
Ortho annotations now show the real-world coordinates when 3D model is externally referenced with a non-origin insert point.
Pipe gap and insulation symbol can now be placed on ortho drawings when 3D model is externally referenced with non-origin insert point.
Spec Editor