LSEQ

Static Load Set Definition

Description: Defines a sequence of static load sets used in transient response analysis.

Format:

Example:

Field Definition Type Default
SID Identification number of the LSEQ set. Integer > 0 Required
DAREA The DAREA set identification number assigned to this static load vector. Integer > 0 Required
LID Load set identification number of a set of static load entries (any entry that may be referenced by the LOAD Case Control command). Integer > 0 or blank See Remark 5
TID Temperature set identification of a set of thermal load entries (any entry that may be referenced by the TEMPERATURE(LOAD) Case Control command). Integer > 0 or blank See Remark 5

Remarks:

  1. LSEQ will not be used unless selected in the Case Control Section with the LOADSET command.
  2. A static load vector will be created for each DAREA identification number referenced by a LSEQ entry.
  3. The DAREA identification assigned to the static load vectors may be referenced by TLOAD1 and TLOAD2 entries.
  4. Element data recovery for thermal loads is not currently implemented in transient response analysis.
  5. LID and TID cannot both be blank.