HEXINODE

Description Type Default

Hex element internal node option. When set to ON, hex elements will produce more accurate results with a small performance degradation. The AUTO setting (default) will use the ON setting for stiffness matrix and stress calculations for models less than DECOMPAUTOSIZE or nonlinear solutions. For models greater than DECOMPAUTOSIZE and AUTO, only the stiffness matrix assembly phase will use the ON setting. The AUTO setting is recommended and provides optimal performance with accuracy.

ON/OFF

AUTO

AUTO