CDAMP1

Scalar Damper Connection

Description: Defines a scalar damper element.

Format:

Example:

Field Definition Type Default
EID Element identification number. Integer > 0 Required
PID Property identification number of a PDAMP property entry. Integer > 0 Required
G1, G2 Grid point identification numbers of connection points. Integer ≥ 0 See Remark 2
C1, C2 Component numbers. 0 ≤ Integer ≤ 6 See Remark 2

Remarks:

  1. Element identification numbers must be unique with respect to all other element identification numbers.
  2. A blank may be used to indicate a grounded terminal G1 or G2 with a corresponding blank or zero C1 or C2. A grounded terminal is a point whose displacement is constrained to zero.
  3. The two connection points (G1, C1) and (G2, C2), must be distinct.
  4. When this entry is used in heat transfer analysis, it generates a lumped heat capacity.
  5. If Gi refers to a grid point, then Ci refers to component numbers in the displacement coordinate system specified by CD on the GRID entry.