Use this dialog to verify steel members subjected to the action of user-defined internal forces, according to the requirements of the Russian steel code SP16.13330.2011. 
  
Access
 
		 
		- Click 
			 Design
Steel Member Design - Options
Verification. 
		   
 
		Note: The SP16.13330.2017 code replaces the former SNiP II-23-81 and SP16.13330.2011 versions of the code for steel structures. Therefore, all references to tables or sections of the code apply to the SP16.13330.2017 code except otherwise stated. 
		
 
	  
Dialog elements
 
		 
		
 
		- Verification of member no. 
			 
 
- Select the member to verify. 
			 
 
-  Internal forces in the analyzed section 
			 
 
- Enter the values of the appropriate internal forces. 
			 
 
- The units applied are displayed in the top right corner of the dialog. 
			 
 
- Internal forces in characteristic cross-sections 
			 
 
- Enter values of the appropriate internal forces on the left and right member ends as well as along the member length. 
			 
 
- The units applied are displayed in the top right corner of the dialog. 
			 
 
- Load level 
			 
 
- Click the Load level icon, and then select a type of load level. 
				
Note: A load level is a load acting on lower or upper flange. 
				
 
			  
- Load Type 
			 
 
- Click the Load Type icon, and then select a type of load. 
			 
 
- Click the Load level icon to select the type of load level. 
			 
 
- Options 
			 
 
- Opens the Configuration dialog, which allows you to set the calculation parameters. 
			 
 
- Calculations 
			 
 
- Runs the calculations. 
			 
 
 
		Once the member verification is complete, a dialog displays the calculation results. 
		
 
		Note: When running a manual verification, the intermediate stiffeners defined in the Member definition dialog are not taken into account, and the member is treated as a member without stiffeners along its length.