Using this option, you can specify manual verification parameters for the defined connection. 
Access the option by: 
- Clicking Connections layout. 
 
- Clicking Connections menu > Manual Calculations. 
 
After you select the option, the Manual Connection Verification dialog displays. 
Specify verification parameters:
- Node number - displays the number of the node for which the selected connection type is verified 
 
- Connection number - displays the number of the verified connection 
 
- Internal Forces in the Connection 
- Bending moment M - enter the bending moment value for a connection 
 
- Shear force Q - enter the shear force value for a connection 
 
- Axial force N - enter the axial force value for a connection 
 
  
- Simplified note - select it to display a simple calculation note with the basic information about the verified connection. 
 
 After clicking the Calculations button the software runs calculations of the selected connection type for a given structure node. Define internal connection forces (M, Q, N). 
See also: 
Directions of Force Operation In Individual Connection Types