Use this option to define additional code parameters for the steel member type according to the South Africa SANS 10162-1:2011 code. Access the parameters by clicking the More button in the Member definition - parameters dialog. 
	 
The following parameters are defined: 
	 
- Load type for directions Y and Z. 
		
 
- Section parameters 
		  
- Anet/Agross ratio. This value applies to a tensile force acting on the cable. It is a coefficient that defines the relationship of the member cross-section area, not considering the bolt or rivet openings (Anet), to the total cross-section area (Agross). 
			 
 
 
		 
- Stiffener spacing for the outermost and intermediate panels. 
		
 
- Round pipes case conditions. If the Unidirectional bending of pipes option is selected, then, for this type of section, a bending moment equal to a sum of moments operating along axis Y and Z is calculated; the resultant moment is the basis for bar design. 
		
 
- Single-angle members in compression (see 
		  Section 13.3.3 
		  of the code). 
		  
By selecting an option from this field you can define a function of single-angle members in a structure and how they are connected with gusset plates. Depending on a selected option, 
			 Robot calculates the equivalent slenderness of the element in compression according to Section 13.3.3. Thus calculated slenderness will be used for the buckling check for the directions Y and Z.