Use this dialog to determine the spacing of transverse stiffeners along the beam length, with real coordinates or in relation to the beam length according to the NBR 8800:2008 code. 
  
Access
 
		 
		- Click 
			 Stiffeners in the Member Definitions - Parameters dialog. 
		  
 
 
	  
Dialog elements
 
		 
		
 
		-  Stiffener distribution along beam length 
			 
 
-  Enter the coordinates of the transverse stiffeners along the beam length, and specify if these coordinates are real or relative to the beam length. 
				
Note:  
				  - Based on positions of transverse stiffeners, the program also calculates the length of the unstiffened web; this information is used to evaluate the shear strength V Rd according to Section 5.4.3. 
					 
 