Swap Pressure Network Parts Dialog Box

Use this dialog box to specify the replacement parts to use, and to specify how the level of the replacement part is determined.

After the parts are replaced, the Design Check command is run automatically to alert you to any issues that may be introduced by the changes. Issues are marked with warning symbols.

Part Source

You can select replacement parts from either the current pressure network parts list or a specific parts catalogue. The parts in the list or catalog that you select will be available for selection in the Replacement Part section of the dialog box.

Parts List
Specifies the current pressure network parts list for part swapping.
Parts Catalog
Specifies a specific parts catalogue to use for part swapping.
Note: If you select a part from a parts catalog, the part is automatically added to the current parts list after the part swapping is completed if it has not already been added.

Replacement Part

Use these options to specify the replacement parts to use.

Note: If you have selected multiple parts whose type and family are different, *VARIES* will appear in the list boxes and you are restricted to specifying the size for the replacement parts.
Part Type
Specifies the part type for the replacement part.
Note: Pressure Pipes can only be replaced with other pressure pipes, fittings with other fittings, and ancillaries with other ancillaries. However, fittings are categorized into elbow, cross, and tee and parts of those subtypes can be swapped with each other. For example, an elbow fitting can be replaced with a cross or a tee fitting.
Part Family
Specifies the subset of the part types to use for the replacement part.
Size
Specifies the size to use for the replacement part.

Level Reference

You can use the Level Reference setting to specify how the level of the replacement part is determined. Path-based pressure networks can only use Outside Top as an Elevation Reference.

Note: In plan view, a replacement part is aligned with the centerline of the existing part.
  • If you specify a specific part Level Reference (Outside Top, Soffit, Centerline, Invert, Outside Bottom), the level of the point on the existing part will be used as the level of the same point on the new part.

    For example, if you select Centerline, the level of the centerline of the original parts is held as the level of the centerline of the replacement parts. In the following illustration which shows the effect in profile view, the blue fitting and pipe have been increased in size and centerline was selected as the Level Reference.

  • If you specify a surface and depth of cover, the level of the replacement part will be placed according to that surface level and cover depth.

For information about how the level reference of pressure networks is established when they are created, see "Establishing Level Information for the Pressure Network" in About Creating Pressure Networks in Plan View.

Outside Top
Specifies that the outside top of the new part is placed at the same level as the outside top of the existing part.

In the following illustration, the fitting and the pipe shown in blue were swapped to a larger size and their outside top levels were held.

Note: The illustrations in this section are shown in profile view. The black pipe on the left was left unchanged in order to illustrate the relative changes in the blue parts. The warning notifications are displayed because this leads to unequal diameters.
Soffit
Specifies that the soffit of the new part is placed at the same level as the soffit of the existing part.

In the following illustration, the fitting and the pipe shown in blue were swapped to a larger size and their soffit levels were held.

Centerline
Specifies that the centerline of the new part is placed at the same level as the centerline of the existing part.

In the following illustration, the fitting and the pipe shown in blue were swapped to a larger size and their centerline levels were held.

Invert
Specifies that the invert of the new part is placed at the same level as the invert of the existing part.

In the following illustration, the fitting and the pipe shown in blue were swapped to a larger size and their invert levels were held.

Outside Bottom
Specifies that the outside bottom of the new part is placed at the same level as the outside bottom of the existing part.

In the following illustration, the fitting and the pipe shown in blue were swapped to a larger size and their outside bottom levels were held.

Depth Of Cover
Specifies that the outside top of the new part is set at a level below the reference surface. Enter the level in the Depth Of Cover box.
Note: If the drawing does not contain any surfaces, this option is not available for selection.

In the following illustration, the fitting and the pipe shown in blue were swapped to a larger size and a depth of cover level was specified.