You can set the current cross section by station value. When the current cross section is set, you can create new points from this occupied point by supplying the offset and level information.
To use the Offset Staff, Offset Level, and Offset Vertical Distance commands, you must set the current cross section chainage.
XS [station]
BEGIN CL1
NE 1 1000 1000
NE 2 1000 1500
NE 3 1300 1700
END
CL IS CL1
XS 350
Current Cross-section Station: 350.00
XS [station]
Parameter | Definition |
---|---|
station | The station to use for subsequent cross section commands. |