Prepare the pipe network for flow rate analysis and sizing
Before analysing and size the pipe network, you must first set up the pipe network and create catchments or determine the known flow. For more information about prerequisites, see About Analysing and Size a Gravity Pipe Network.
To analyze and size a pipe network for specified rainfall data
Click the Analyze tab Design panel Analyze Gravity NetworkFind.
Select the pipe network you want to analyze. You can select the network in the drawing or press Enter and select the pipe network from the Select Pipe Network dialog box.
After you select the pipe network, the Analyse Gravity Network dialog box is displayed.
Note: If the selected pipe network is data-referenced, the energy and hydraulic gradient lines can be computed, but analysis results cannot be applied to the pipe network.
On the General page, review and specify the following items:
Analysis types to run
Outfall part
Tailwater condition
Rainfall data
Click Settings to open the Settings page where you can specify settings to use in the analysis.
Click Network Details to open the Network Details page where you can specify settings and values for the pipes and structures.
Note: To edit multiple rows in a column, hold down the Ctrl or Shift keys when selecting the rows and then keep the Shift key pressed when you click the column.
Click the Analyse button at the bottom of the dialog box to process the analysis.
On the Results page, you can review the results and preview the changes in profile view, you can output a report of the results to a .csv file and you can apply the results to the pipe network.