About Default Cleanup Priorities of Wall Components

The component priority determines how each wall component cleans up with the components of an intersecting wall. The lower the component index number, the higher the priority of the component when it intersects other walls.

Wall cleanup priorities

The following table lists the default cleanup priority for components used in sample wall styles provided in AutoCAD Architecture 2022 toolset catalogs. You can assign different priorities to wall components in wall styles and individual walls to control cleanup with other walls.

Component Index
Air Gap 700
Air Gap (Brick/Brick) 805
Air Gap (CMU/CMU) 305
Air Gap (Stud/Stud) 505
Brick 800
Brick Veneer 810
Bulkhead 1800
Casework - Backsplash 2030
Casework - Base 2010
Casework - Counter 2020
Casework - Upper 2000
CMU 300
CMU Veneer 350
Concrete 200
Concrete (Footing) 200
Glass 1200
GWB 1200
GWB (X) 1200,1210,1220,1230
Insulation (CMU/Brick, Stud/Brick) 600
Metal Panel 1000
Precast Panel 400
Rigid Insulation (Brick) 404
Siding 900
Stucco 1100
Stud 500
Toilet Partition 3000