Schematic tab - Power Check Tools panel

The Power Check Tools panel is off by default.

 

Command

Description

Add/Edit Power Source/Load Levels

AEPOWERLOADLEVELS

Marks a component with a power source and load value. A related routine, when invoked, then scans the wire interconnections and reports if there is too much load on a given power source

Mark Component To Pass Power

AEPASSPWR

Marks a component with a PASSPWR flag. The PASSPWR flag instructs the Power Report to pass through the marked component when calculating the load on a given source. If a component carries the PASSPWR flag the Power Report program will pass through the component and continue looking for load values on the network.

Note:

Certain components don't need a PASSPWR flag (such as terminals and contacts) since they are automatically passed through.

Power Load Check Report

AEPOWERLOADREPORT

Scans the wire interconnections and reports if there is too much load on a given power source.