The Power Check Tools panel is off by default.
Command |
Description |
|
---|---|---|
Add/Edit Power Source/Load Levels AEPOWERLOADLEVELS |
Marks a component with a power source and load value. A related routine, when invoked, then scans the wire interconnections and reports if there is too much load on a given power source |
|
Mark Component To Pass Power AEPASSPWR |
Marks a component with a PASSPWR flag. The PASSPWR flag instructs the Power Report to pass through the marked component when calculating the load on a given source. If a component carries the PASSPWR flag the Power Report program will pass through the component and continue looking for load values on the network.
Note:
Certain components don't need a PASSPWR flag (such as terminals and contacts) since they are automatically passed through. |
|
Power Load Check Report AEPOWERLOADREPORT |
Scans the wire interconnections and reports if there is too much load on a given power source. |