New Module Dialog Box

Defines the module descriptions and parameters.

Find
 Command entry:  AEPLCDB

Click New Module.

New Module Controls

Specifies the Manufacturer, Series, Series Type, and Code (Catalog Number) for the new module. Select from the list or enter the name in the edit box.

Note: If you right-click a type or module in the PLC Selection window and select New Module, the New Module dialog box opens with data already specified for the Manufacturer, Series, and Series Type.

PLC Selection Expanded Description Listing Controls

These controls display as an expanded description when the module is highlighted in the tree structure of the PLC Selection dialog box. They include:

Description

Describes the PLC module being defined.

Module Type

Gives an abbreviated type to the PLC module.

Base Addressing

Specifies whether the PLC module addressing follows an industry standard. Select from Octal, Decimal, Hexadecimal, and Prompt. Prompt asks you at module insertion time for Octal, Decimal, and Hexadecimal.

Rating

Specifies the power rating value for the PLC module.

Terminals

Specifies the total number of terminals defined on the PLC module.

Note:

It is not active since it is under the control of the total number of terminals listed in the Terminal Type grid control.

Addressable Points

Specifies the total number of termination points on the PLC module that receives the PLC address attributes.

AutoCAD Block to insert

Specifies an AutoCAD block file to insert directly below the last I/O point inserted parametrically. They are typically used for block files that represent DIP switch settings and notes on how to configure the PLC module.

AutoLISP file to run at module insertion time

Specifies an AutoCAD Lisp routine to run after the program executes the parametric build of the PLC module. They are typically used for inserting groups of symbols and wires, or modifying attributes on symbols to accommodate a more custom PLC module build.

Module Box Dimensions

Opens a dialog box for defining the outer box dimensions of the module. The box dimensions are calculated from the insertion point of the parametrically built PLC symbols.

Module Prompts