Select Load Dialog Box

Browse the load table and select the appropriate load and annotation values. You can also modify the lookup table.

Find
 Command entry:  AECIRCBUILDER

On the Select Circuit dialog box, select a power feed circuit, click Configure, and then select the Load Setup Browse button.

Type

Filter the listing based on load type. Select <All> from the list to turn off filtering for this field.

Voltage (V)

Filter the listing based on voltage. Select <All> from the list to turn off filtering for this field.

Phase

Filter the listing based on phase. Select <All> from the list to turn off filtering for this field.

Selection grid

Select a load to pass the values back to the Circuit Configuration dialog box.

Edit or add records

Specifies whether you can edit or select the values. Values you edit are written back to the electrical standards database file.

Temporarily closes the dialog box so that you can select an existing power feed load symbol and reuse its values.

FLA

Displays or sets the full load amps (FLA) value. The FLA value is multiplied by the FLA Multiplier value to calculate the Maximum load value.

FLA multiplier

Sets the multiplier factor. The FLA value is multiplied by this value to calculate the Maximum load value.

Maximum load

Displays the calculated maximum load based on the product of FLA and FLA multiplier.

Note: The initial default values used for Voltage and the FLA multiplier are controlled from the active OPT table in the electrical standards database file.