To Add Individual Part Sizes to a Parametric Air Terminal MvPart

Use this procedure to add individual part sizes to the model. You create individual part sizes by adding parameters values. Values can be a list or table of values, constant values, or calculations.

You can also create unique part size names. Each part size name is generated using a calculation—a formatted string of parameter values and text.

  1. To add part sizes to the part, in the part browser, right-click Size Parameters, and click Edit Configuration.

    The Size Parameters dialog box is displayed.

    Note: Calculated values set in the model cannot be edited in the Size Parameters dialog box. To change these values you must edit the model.
  2. To add a table of available sizes for the lengths and widths of the top and bottom faces of the diffuser, change the data storage type of the LenA1, LenA2, LenA3, and LenA4 parameters to Table.
  3. In the toolbar, select Values from the list.

    The parameter values are displayed.

  4. To add a new part size, click the first row in the table, and then click on the toolbar.

    A new part size row is added to the Size Parameters dialog box. Repeat for each new part size you want to add.

  5. For each part size, double-click in the LenA1, LenA2, LenA3, and LenA4 parameters and enter values.
    Tip: You can copy and paste values from other part families using standard Microsoft® Windows copy and paste functionality (Ctrl+C for Copy and Ctrl+V for Paste). You can copy and paste values from another part open in Content Builder, from a part open in Catalog Editor, or from a Microsoft® Excel spreadsheet. For connector parameters, you can also insert the corresponding values for the segments used by default during layout.
  6. When you finish adding sizes, click OK.
  7. To add the size of the transition between faces, expand Model Parameters, right-click WPOf1, and click Edit.
  8. In the Model Parameters dialog box, double-click the Equation value for WPOf1, enter -4" (-102 mm), and click Close.
    Note: You can also add an equation formula for the value. Click Calculator to access the Equation Assistant.
  9. To specify a unique part size name, in the part browser, right-click Size Parameters and click Edit Calculations.

    The Size Parameters dialog box is displayed.

  10. Double-click PrtD in row 1.

    The Calculation Assistant is displayed.

  11. In the Calculation Assistant, define the part size name.
    • Select 0 for Precision.
    • Under Insert Variable, select LenA1 and click Insert.
    • At the top of the dialog box, click the value for Part Size Name (PrtSN), and enter x.
    • Under Insert Variable, select LenA2, and click Insert.
    • Click the value for Part Size Name (PrtSN), and enter inch Louver Face Ceiling Diffuser.
  12. Click Evaluate to view the result.
  13. Click OK twice.