In this exercise, you will add a data band, which is an optional graphic frame that is associated with the section view.
This exercise continues from Exercise 2: Adding a Section View Grade Label.
Add a data band to a section view
The name of the Corridor (1) Top surface varies depending on the section view that you are editing.
A data band is added to the section view in the drawing. Notice that there is no data displayed in the band. This happened because the default Weeding factor specifies that any section segments that are less than 100 drawing units long are not displayed in the band. In the next step, you will reduce the Weeding factor and examine the results.
Segment lengths that are greater than 5 drawing units long are annotated in the new data band.