Exercise 3: Adding a Data Band to a Section View

In this exercise, you will add a data band, which is an optional graphic frame that is associated with the section view.

This exercise continues from Exercise 2: Adding a Section View Grade Label.

Add a data band to a section view

  1. Open Section-Data-Band.dwg, which is located in the tutorials drawings folder.
  2. Select the section view. Right-click. Click Section View Properties.
  3. On the Section View Properties dialog box, on the Bands tab, specify the following parameters:
    • Band Type: Section Segment
    • Select Band Style: FG Segments
  4. Click Add.
  5. In the List of Bands table, scroll to the right and click the Section 1 cell for the new band that you created. From the drop-down list, select the Corridor (1) Top surface.
    Note:

    The name of the Corridor (1) Top surface varies depending on the section view that you are editing.

  6. Click Apply.

    A data band is added to the section view in the drawing. Notice that there is no data displayed in the band. This happened because the default Weeding factor specifies that any section segments that are less than 100 drawing units long are not displayed in the band. In the next step, you will reduce the Weeding factor and examine the results.

  7. In the Section Segment row, change the Weeding value to 5.0000.
  8. Click OK.

    Segment lengths that are greater than 5 drawing units long are annotated in the new data band.