Test/Abort/Continue/Remachine

Comment — The comment is output in the NC code at the start of the test feature.

Nominal Value — Enter the measurement that you are testing, for example the diameter of a Bore feature.

Nominal Value Register — This is the register that the machine uses to store the Nominal Value

Remachine Flag Register — This is the register where the machine stores the count for the number of times the feature is remachined.

Result Register — This is the register where the machine stores the result of the probing measurement.

Continue Label — This is the label to jump to, to continue machining.

Remachine Label — This is the label to jump to, to remachine the feature.

Temporary Register — This is used to store any temporary logic needed to process the decision-making feature.