Orphaned LP existence for Factory

When you uninstall an Autodesk Factory Beta release, the language pack may not fully be removed from your system. This prevents any future successful installations of Autodesk Factory.

To resolve the problem:

  1. Uninstall the orphaned language packs using Windows Control Panel.
  2. Reinstall Factory.
  3. If you are prompted to remove language packs but there are no language pack entries in the Control Panel, open a CMD window and uninstall any remaining language pack using the command line:

Identify the corresponding 3-digit language product code for the orphaned language pack from the below product code table.

Language Factory Design 2022 (64bit) Product Code
enu(English) Factory Design for AutoCAD: {50C4286A-0010-2410-1033-E4D83F8ED286}

Factory Design Inventor Server: {4A72D125-0010-2410-1033-2619887346E3}

Factory Design for Inventor: {5D3318B4-0010-2410-1033-7082DE7B6CBB}

Factory Design for Navisworks: {1D815D1E-0010-2410-1033-D21F654E6AD9}

Factory Design for Vault: {471F3FA2-0010-2410-1033-30F7ED6A8BDC}
chs(Chinese Simplify) Factory Design for AutoCAD: {50C4286A-0010-2410-2052-E4D83F8ED286}

Factory Design Inventor Server: {4A72D125-0010-2410-2052-2619887346E3}

Factory Design for Inventor: {5D3318B4-0010-2410-2052-7082DE7B6CBB}

Factory Design for Navisworks: {1D815D1E-0010-2410-2052-D21F654E6AD9}

Factory Design for Vault: {471F3FA2-0010-2410-2052-30F7ED6A8BDC}
cht(Chinese Traditional) Factory Design for AutoCAD: {50C4286A-0010-2410-1028-E4D83F8ED286}

Factory Design Inventor Server: {4A72D125-0010-2410-1028-2619887346E3}

Factory Design for Inventor: {5D3318B4-0010-2410-1028-7082DE7B6CBB}

Factory Design for Navisworks: {1D815D1E-0010-2410-1028-D21F654E6AD9}

Factory Design for Vault: {471F3FA2-0010-2410-1028-30F7ED6A8BDC}
csy(Czech) Factory Design for AutoCAD: {50C4286A-0010-2410-1029-E4D83F8ED286}

Factory Design Inventor Server: {4A72D125-0010-2410-1029-2619887346E3}

Factory Design for Inventor: {5D3318B4-0010-2410-1029-7082DE7B6CBB}

Factory Design for Navisworks: {1D815D1E-0010-2410-1029-D21F654E6AD9}

Factory Design for Vault: {471F3FA2-0010-2410-1029-30F7ED6A8BDC}
deu(German) Factory Design for AutoCAD: {50C4286A-0010-2410-1031-E4D83F8ED286}

Factory Design Inventor Server: {4A72D125-0010-2410-1031-2619887346E3}

Factory Design for Inventor: {5D3318B4-0010-2410-1031-7082DE7B6CBB}

Factory Design for Navisworks: {1D815D1E-0010-2410-1031-D21F654E6AD9}

Factory Design for Vault: {471F3FA2-0010-2410-1031-30F7ED6A8BDC}
esp(Spanish) Factory Design for AutoCAD: {50C4286A-0010-2410-3082-E4D83F8ED286}

Factory Design Inventor Server: {4A72D125-0010-2410-3082-2619887346E3}

Factory Design for Inventor: {5D3318B4-0010-2410-3082-7082DE7B6CBB}

Factory Design for Navisworks: {1D815D1E-0010-2410-3082-D21F654E6AD9}

Factory Design for Vault: {471F3FA2-0010-2410-3082-30F7ED6A8BDC}
fra(French) Factory Design for AutoCAD: {50C4286A-0010-2410-1036-E4D83F8ED286}

Factory Design Inventor Server: {4A72D125-0010-2410-1036-2619887346E3}

Factory Design for Inventor: {5D3318B4-0010-2410-1036-7082DE7B6CBB}

Factory Design for Navisworks: {1D815D1E-0010-2410-1036-D21F654E6AD9}

Factory Design for Vault: {471F3FA2-0010-2410-1036-30F7ED6A8BDC}
ita(Italian) Factory Design for AutoCAD: {50C4286A-0010-2410-1040-E4D83F8ED286}

Factory Design Inventor Server: {4A72D125-0010-2410-1040-2619887346E3}

Factory Design for Inventor: {5D3318B4-0010-2410-1040-7082DE7B6CBB}

Factory Design for Navisworks: {1D815D1E-0010-2410-1040-D21F654E6AD9}

Factory Design for Vault: {471F3FA2-0010-2410-1040-30F7ED6A8BDC}
jpn(Japanese) Factory Design for AutoCAD: {50C4286A-0010-2410-1041-E4D83F8ED286}

Factory Design Inventor Server: {4A72D125-0010-2410-1041-2619887346E3}

Factory Design for Inventor: {5D3318B4-0010-2410-1041-7082DE7B6CBB}

Factory Design for Navisworks: {1D815D1E-0010-2410-1041-D21F654E6AD9}

Factory Design for Vault: {471F3FA2-0010-2410-1041-30F7ED6A8BDC}
kor(Korean) Factory Design for AutoCAD: {50C4286A-0010-2410-1042-E4D83F8ED286}

Factory Design Inventor Server: {4A72D125-0010-2410-1042-2619887346E3}

Factory Design for Inventor: {5D3318B4-0010-2410-1042-7082DE7B6CBB}

Factory Design for Navisworks: {1D815D1E-0010-2410-1042-D21F654E6AD9}

Factory Design for Vault: {471F3FA2-0010-2410-1042-30F7ED6A8BDC}
pol(Polish) Factory Design for AutoCAD: {50C4286A-0010-2410-1045-E4D83F8ED286}

Factory Design Inventor Server: {4A72D125-0010-2410-1045-2619887346E3}

Factory Design for Inventor: {5D3318B4-0010-2410-1045-7082DE7B6CBB}

Factory Design for Navisworks: {1D815D1E-0010-2410-1045-D21F654E6AD9}

Factory Design for Vault: {471F3FA2-0010-2410-1045-30F7ED6A8BDC}
ptb(Brazilian Portuguese) Factory Design for AutoCAD: {50C4286A-0010-2410-1046-E4D83F8ED286}

Factory Design Inventor Server: {4A72D125-0010-2410-1046-2619887346E3}

Factory Design for Inventor: {5D3318B4-0010-2410-1046-7082DE7B6CBB}

Factory Design for Navisworks: {1D815D1E-0010-2410-1046-D21F654E6AD9}

Factory Design for Vault: {471F3FA2-0010-2410-1046-30F7ED6A8BDC}
rus(Russian) Factory Design for AutoCAD: {50C4286A-0010-2410-1049-E4D83F8ED286}

Factory Design Inventor Server: {4A72D125-0010-2410-1049-2619887346E3}

Factory Design for Inventor: {5D3318B4-0010-2410-1049-7082DE7B6CBB}

Factory Design for Navisworks: {1D815D1E-0010-2410-1049-D21F654E6AD9}

Factory Design for Vault: {471F3FA2-0010-2410-1049-30F7ED6A8BDC}

Or, open the CMD window and input the command to uninstall the orphaned language pack manually. Replace the product code with the corresponding orphaned language pack product code.

For example, to remove the Factory Design for AutoCAD English language pack, enter:

Msiexec /x {50C4286A-0010-2410-1033-E4D83F8ED286}