Clevis Pin Generator dialog box - Calculation tab

This tab extends the Design tab. You can calculate generator data based on selections in the Design tab.

Access:

Ribbon: Design tab Fasten panel Clevis Pin and click the Calculation tab.
Note: The Calculate command is available only if a pin is selected.

Type of Strength Calculation

Select the calculation method. It determines which parameters are input parameters and which parameters to calculate.

Note: The selection list is enabled only when pin is selected.

Clevis Pin Design

Designs the optimum clevis pin dimensions for the specified load, dimensions and joint properties.

Check Calculation

Strength check for the specified load, dimensions, and joint properties.

Loads

Use Force F to enter Loading.

Dimensions

Pin Diameter

Choose a diameter of the pin.

Pin Length

Choose a length of the pin.

Clevis Width

Choose the width of the clevis. Based on this dimension the appropriate clevis pin is selected, you can manually type the diameter or measure the diameter from ProdName using the options displayed after clicking the arrow next to edit field.

Rod Width

Choose the width of the rod. Enter the width of the clevis rod according to the part dimensions. If the sum of the clevis and rod widths is not equal to the working pin length, the unequal widths turn red. This also indicates that the strength check of the pin is not satisfactory. Based on this dimension the appropriate rod is selected, you can manually type the diameter or measure the diameter from ProdName using the options displayed after clicking the arrow next to edit field.

Note: The values in the edit field that are not satisfactory turn red when the Calculate command is pressed.

Joint Properties

Service Factor

Represents a Type of Loading and type of Mounting. The allowed material value is lowered according to the selected type. Click next to edit field to open the Service Factor dialog box where you can select the Service Factor value.

Desired Safety

With regards to accuracy and credibility of input information, importance of the coupling, quality of production and accuracy of the calculation, it is chosen in a range from 1.5 to 10.

Pin Material

 

Warning: Strength parameters of material are determined empirically and reflect minimum values applicable for a group of materials. Although these values are close to the values obtained using measurement of particular materials, we recommend in cases of final calculations to use parameters of material according to the material sheet or specifications of the producer.

Material

You can specify your own material values or select a material from Material Database.

If a material is selected from the Material Database, its values are inserted automatically into the following 3 edit fields, and the edit fields are locked. To unlock the field, clear the check box.

Allowable Bending Stress

Specifies allowable pin bending stress used in calculation. The clevis pin is checked for bending during the strength check.

Allowable Shear Stress

Specifies allowable pin shear stress used in calculation. The clevis is checked for shear during the strength check.

Clevis Material

Material

You can specify your own material values or select a material from the Material Database.

If a material is selected from the Material Database, its values are inserted into the following 3 edit fields, and the edit fields are locked. To unlock the field clear the box.

Allowable Pressure

Enters the allowable pressure of the clevis pin material with the least quality in the Joint Properties group. The clevis is checked for pressure during the strength check.

Rod Material

Material

You can specify your own material values or select a material from Material Database.

If a material is selected from Material Database, its values are inserted into the following 3 edit fields, and the edit fields are locked. To unlock the field clear the box.

Allowable Pressure

Enter the allowable pressure of the rod material with the least quality in the Joint Properties group. The rod is checked for pressure during the strength check.

Results

To display the Results area on the right side of the Calculation tab, double-click the double line on the right or click the chevron.

The area displays the calculated values and the clevis pin strength check. Values are calculated when you click Calculate.

The units of the results values can be changed. Double-click the specified value you want to change.

Summary of Messages

Displays the reports about calculations. To open the Summary of Messages area at the bottom of the Calculation and Design tabs, double-click the double line at the bottom of tabs or click the chevron.

Design tab

Service Factor

Menu Commands