Description
The BSCONP entry defines the parameters for a surface contact region.
Format
| 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 |
| BSCONP | CRID | SLAVE | MASTER | SFACT | CAPTOL | MU | PTYPE | MAXAD |
Example
| BSCONP | 11 | 2 | 5 | 0.2 | 2 |
| Field | Definition | Type | Default |
|---|---|---|---|
| CRID | Contact region identification number. | Integer > 0 | Required |
| SECONDARY | Secondary region identification number. This is the CSID for a BSSEG entry or a generated contact surface. | Integer > 0 | Required |
| PRIMARY | Primary region identification number. This is the CSID for a BSSET entry or a generated contact surface. | Integer > 0 | Required |
| SFACT | Stiffness scaling factor. The stiffness scaling factor is used to scale the penalty values. The penalty values are determined automatically. See Remark 4. | 0 < Real ≤ 1.0 | 0.2 |
| CAPTOL | Capture tolerance parameter for tied contact pairs. This value is used for tied contact. Regions of opposing contact surfaces within a distance controlled by this parameter are tied together. See Remark 6. | Real ≥ 0.0 | 0.05 |
| MU | Coefficient of static friction. | Real ≥ 0.0 | 0.0 |
| PTYPE |
Penetration type: 1 = Unsymmetric general contact (secondary penetration only) 2 = Symmetric general contact 3 = Unsymmetric welded contact 4 = Symmetric welded contact |
1 ≤ Integer ≤ 4 | 1 |
| MAXAD | Maximum activation parameter: See Remark 5. | Real ≥ 0.0 | 0.5 |
Remarks