Description
The TIC entry defines values for the initial conditions of variables used in transient response analysis. Both displacement and velocity may be specified at independent degrees of freedom. Note that the INITVEL entry and the ROTVEL entry can be used as an alternative to the TIC entry to define initial velocities for parts of the model in a more convenient form.
Format
| 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 |
| TIC | SID | G | C | U0 | V0 |
Example
| TIC | 10 | 25 | 2 | 12.5 | -5.0 |
| Field | Definition | Type | Default |
|---|---|---|---|
| SID | Set identification number. | Integer > 0 | Required |
| G | Grid point identification number. | Integer > 0 | Required |
| C | Component number of global coordinate (up to six unique digits may be placed in the field with no embedded blanks.) | 0 ≤ Integer ≤ 6 | Required |
| U0 | Initial displacement. | Real | 0.0 |
| V0 | Initial velocity. | Real | 0.0 |
Remarks