CELAS4

Scalar Spring Property and Connection to Scalar Points Only

Description: Defines a scalar spring element that is connected only to scalar points and without reference to a property entry.

Format:

Example:

Field Definition Type Default
EID Element identification number. Integer > 0 Required
K Stiffness value. Real Required
S1, S2 Scalar point identification numbers of connection points. Integer > 0 See Remark 2
GE Structural element damping coefficient. See Remark 4. Real or blank 0.0
S Stress coefficient. Real or blank 0.0

Remarks:

  1. Element identification numbers must be unique with respect to all other element identification numbers.
  2. A blank may be used to indicate a grounded terminal G1 or G2 with a corresponding blank or zero C1 or C2. A grounded terminal is a point whose displacement is constrained to zero.
  3. This single entry completely defines the element since no material or geometric properties are required.
  4. If Gi refers to a grid point, then Ci refers to component numbers in the displacement coordinate system specified by CD on the GRID entry.
  5. If PARAM, W4 is not specified, GE is ignored in transient response analysis. (See Section 5, Parameters, for more information on W4.)
  6. To obtain the damping coefficient GE, multiply the critical damping ratio C/C0, by 2.0.