Scalar Spring Property and Connection to Scalar Points Only
Description: Defines a scalar spring element that is connected only to scalar points and without reference to a property entry.
Format:
Example:
Field
|
Definition
|
Type
|
Default
|
EID
|
Element identification number.
|
Integer > 0
|
Required
|
K
|
Stiffness value.
|
Real
|
Required
|
S1, S2
|
Scalar point identification numbers of connection points.
|
Integer > 0
|
See Remark 2
|
GE
|
Structural element damping coefficient. See Remark 4.
|
Real or blank
|
0.0
|
S
|
Stress coefficient.
|
Real or blank
|
0.0
|
Remarks:
- Element identification numbers must be unique with respect to all other element identification numbers.
- A blank may be used to indicate a grounded terminal G1 or G2 with a corresponding blank or zero C1 or C2. A grounded terminal is a point whose displacement is constrained to zero.
- This single entry completely defines the element since no material or geometric properties are required.
- If Gi refers to a grid point, then Ci refers to component numbers in the displacement coordinate system specified by CD on the
GRID entry.
- If PARAM, W4 is not specified, GE is ignored in transient response analysis. (See Section 5,
Parameters, for more information on
W4.)
- To obtain the damping coefficient GE, multiply the critical damping ratio C/C0, by 2.0.