BAROR

CBAR Entry Default Values

Description: Defines default values for field 3 and fields 6 through 8 of the CBAR entry.

Format:

Example:

Alternate Format and Example:

Field Definition Type Default
PID Property identification number of a PBAR entry. Integer > 0 Required
X1, X2, X3 Components of vector , from GA, in the displacement coordinate system at GA (see Figure 1 in the CBAR entry). Real or blank
G0 Grid point identification number to optionally supply X1, X2, and X3. Direction of orientation vector is GA to G0. Integer or blank

Remarks:

  1. The contents of fields on this entry will be assumed for any CBAR entry whose corresponding fields are blank.
  2. Only one BAROR entry is allowed.
  3. If field 6 is an integer, then G0 is used. If field 6 is blank or real, then X1, X2, X3 is used.