Connects two adjacent components with a new joint.
Use the PLANTCONNECTJOINT command to connect adjacent pipe and fittings. You can connect only those pipe components that have open ports. The open ports must be in-line and at the same location.
If a connection cannot be made when routing pipe, you can display an error message that explains why the joint is not created.
The following prompts are displayed.
Selects a pipe component with an open port that you want to connect.
Selects the adjacent pipe component.
If a connection can be made, a connector object (for example: a Buttweld) is added and the open port markers are removed. If a connection cannot be made because of a property mismatch, the property values are listed in a dialog box.