To add an off-page connector to a line segment
- In the P&ID tool palette, Non-Engineering tab, under Connectors, click Off-Page Connector.
- In the drawing area of a drawing, click near the end of a line to select a location for the off-page connector. The off-page connector snaps to the end of the line with a status of unconnected.
To use off-page connectors to connect line segments in two drawings
The line segments in both drawings must have associated off-page connectors. Their status icons show them as unconnected.
- Right-click the off-page connector. Click Off-page Connector Connect.
- In the Create Connection dialog box, click the drawing that contains the line you want to continue on or from.
- Click the row that contains the off-page connector to which you want to connect. Click OK. The status icons in both drawings changes to connected .
Note: You cannot connect to an unassigned line.
To add text to an off-page connector
- To have the TO and FROM drawing numbers display automatically within each connector, in the Project Manager, right-click each drawing and click Properties. In the DWG Number field, enter the drawing number as you want it to appear.
- To display other connector information, right-click the connector and click Properties. Under General, enter information in the following fields:
- Connector Number
- Origin or Destination