To Work With Multi-Port (Hygienic) Valves

These procedures assume that you have installed a content pack that includes multi-port valves and compatible piping.

Place a Multi-Level Valve

Unlike other valves, multi-level valves are oriented as if laid flat on the ground as opposed to head-up.

If you do not have piping available to connect to, follow these steps:
  1. Begin placing a valve.
  2. Press Ctrl to select a port. If possible, select a top-level port.
  3. In the drawing, specify an insertion point.
  4. Enter p to set the rotation plane.
  5. Click to rotate and place the valve.

Create a Closely Coupled Valve Group

  1. Select and copy a valve.
  2. For the start point, use node snap (nod) to specify a port on one side of the valve.
  3. For the second point, specify a port on the other side of the valve.
  4. Repeat to create a valve group.

Set Port Orientation in a Multi-Level Valve

When you place multi-level valves, you can orient the valve relative to the top section of the valve housing.

Default orientation of a 3-level mixproof divert valve

If you need to set the orientation of the lower sections, follow these steps:

  1. In the Properties palette, verify that TYPE=VALVE-MULTIWAY is set.

    If this is not set, the levels cannot be oriented independently.
  2. In Part Geometry, in Dimensions, enter an angle (for example, enter 270 for A2).

Level 3 (A2) set to 270 degrees

Note: If possible, place your valve relative to a port at the top of the housing. This avoids needing to re-orient the valve after specifying lower-level housing angles in the Properties palette.