In the Revit.ini file, settings in the [UserInterface] section control various aspects of the user interface. Some settings correspond to settings on the User Interface tab of the Options dialog.
Corresponds to Display the contextual tab on selection under Tab Switching Behavior on the User Interface tab of the Options dialog.
Type = integer
Valid values: 0 = no, 1 = yes
Controls the filter list in dialogs that display lists of categories, such as the Visibility/Graphics dialog.
Type = integer
Default value: 31
Valid values include the following. Use other values to indicate various combinations of these settings.
Values for UI settings
Enables or disables the ability to save changes to the Properties palette by moving the cursor out of the palette without clicking Apply.
Type = integer
Valid values: 0 = AutoApply is enabled, 1 = AutoApply is disabled
Enables and disables specific parts of the user interface in Autodesk Revit. This setting corresponds to the Tools and analyses settings in the Configure section on the User Interface tab of the Options dialog.
Type = an integer representing the sum of the values for the UI settings (tools and analyses) to enable. You can use the Revit User Interface Configuration Calculator to calculate the value.
Default value = 32253 (enable all tools and analyses)
Values for UI settings
Example: Structure tab and tools (256) + Structural analysis tab and tools (1) + Energy analysis and tools (2048) = 2605
Corresponds to Enable Recent Files List at Home on the User Interface tab of the Options dialog. To hide the Recent Files list on the Home page, define this setting to 0 (zero).
Type = integer
Valid values: 0 = disable, 1 = enable (default)
Type = string
Prevents users from changing user interface configuration options on the Options dialog, User Interface tab, under Tools and analyses.
Type = integer
Valid values: 0 = no, do not lock (default); 1 = yes, prevent users from changing user interface configuration options
Allows you to rename a view, schedule, sheet, or group with a slow double-click in the Project Browser. (A fast double-click opens it; a slow double-click renames it.)
This feature is turned on by default. To disable renaming with a slow double-click, add the setting to the [UserInterface] section and set it to 0 (zero).
Type = integer
Valid values: 0 = disable, 1 = enable (default)
Corresponds to the Family Editor option in the Tab Switching Behavior section of the User Interface tab on the Options dialog.
Type = integer
Value values: 0 = no (return to the previous tab), 1 = yes (stay on the Modify tab)
Corresponds to the Project Environment option in the Tab Switching Behavior section of the User Interface tab on the Options dialog.
Type = integer
Value values: 0 = no (return to the previous tab), 1 = yes (stay on the Modify tab)
[UserInterface] DisplayRecentFilesPage=0 DisciplineOption=6637 LockDisciplineOption=1 CategoryDisciplineFilter=28 ActivateContextualTabOnSelection=0 StayOnTheModifyTabInProjectEnvironment=1 StayOnTheModifyTabInFamilyEditor=0 DisableMppAutoApply=0