Scalar Mass Connection
Description: Defines a scalar mass element.
Format:
Example:
Field
|
Definition
|
Type
|
Default
|
EID
|
Element identification number.
|
Integer > 0
|
Required
|
PID
|
Property identification number of a
PMASS entry.
|
Integer > 0
|
Required
|
G1, G2
|
Grid point identification numbers of connection points.
|
Integer > 0
|
See Remark 2
|
C1, C2
|
Component numbers.
|
0 ≤ Integer ≤ 6
|
See Remark 2
|
Remarks:
- Element identification numbers must be unique with respect to all other element identification numbers.
- A blank may be used to indicate a grounded terminal G1 or G2 with a corresponding blank or zero C1 or C2. A grounded terminal is a point whose displacement is constrained to zero.
- The two connection points (G1, C1) and (G2, C2) must not be coincident.
- A scalar point specified on this entry need not be defined on an
SPOINT entry.