PDAMPT

Frequency-Dependent Damper Property

Description: Defines the frequency-dependent properties for a PDAMP Bulk Data entry.

Format:

Example:

Field Definition Type Default
PIDi Identification number of a PDAMP entry. Integer > 0 Required
TBID1 Identification number of a TABLEDi entry that defines the damping force per-unit velocity versus frequency relationship. Integer > 0 Required

Remarks:

  1. PDAMPT may only be referenced by CDAMP1 or CDAMP3 elements.
  2. The PDAMPT entry is ignored in all solution sequences except for frequency response analysis.