Rigid Pin-Ended Element Connection
Description: Defines a pin-ended element that is rigid in translation.
Format:
Example:
Field
|
Definition
|
Type
|
Default
|
EID
|
Element identification number.
|
Integer > 0
|
Required
|
GA, GB
|
Grid point identification number of connection points.
|
Integer > 0
|
Required
|
CMA, CMB
|
Component number of one and only one dependent translational degree of freedom in the global coordinate system assigned by the user to either GA or GB.
|
1 ≤ Integer ≤ 3
|
Either CMA or CMB has a single value, the other must be blank
|
Remarks:
- A dependent degree of freedom assigned by one element cannot be assigned dependent by another rigid element or
MPC entry and cannot be additionally constrained (e.g., single-point constraint).
- Degrees of freedom declared to be independent by one rigid body element can be made dependent by another rigid body element or by a multipoint constraint.
- Rigid elements, unlike MPCs, are not selected through the Case Control Section.
- Forces of multipoint constraint may be recovered with the
MPCFORCES Case Control command.