Defines the default wire connection text format.
FindClick Panel wire connection report XYZ offset reference Setup.
After you add wire numbers to your schematics and extract this information, you are ready to annotate your panel footprint symbols with this information. The information is added to the drawing in two different ways:
There are two format edit boxes on the dialog box. The "Full" format is used if AutoCAD Electrical toolset does not find the target attributes and inserts MTEXT. The "Partial" format is used if AutoCAD Electrical toolset finds the target attributes (described later). Each format uses parameters that are then replaced with the specific wire information. AutoCAD Electrical toolset provides some pre-defined formats for you to select from the list box at the right. Or you can enter your own format using replaceable parameters.
Parameters must be separated by nonblank delimiters for AutoCAD Electrical toolset to be able to re-extract wiring diagram information into reports. For example, "%T=%W %1 %G" is not acceptable because there is only a space between the %W and %1 and %G parameters. Acceptable formats include "%T=%W (%1) %G" or "%T=%W / %1 (%G)" or "%T=%W (%1) %G".
Additional options to include in the text.
Add terminal pin as a suffix to tag |
Adds the terminal text as a suffix. |
Add terminal description to tag |
Adds any terminal description value as a suffix. |
Include installation prefix to IEC tag format |
Adds any installation value as a prefix. |
Allows a preview or test of the report.
Indicates to hide duplicated annotations so that they do not show on the report.