To Configure Mechanical Parts for Analysis

You can assign air flow values to duct system equipment, such as air terminals. The duct system can be analyzed, and sizes can be calculated using these values.

  1. Select the part.
  2. Click Equipment tab Modify panel Equipment Properties .
  3. In the Multi-view Part Properties dialog box, click the Flow tab and specify the airflow values:
    To… then…
    specify an air flow value for an outlet device, such as a ceiling diffuser enter the value for Flow.
    specify an air flow value for a supply device, such as a VAV box specify an air flow value for each connector.