To Configure System Definitions for 1-Line, 2-Line, or Single Line Graphics

To specify 1-line

To specify 2-line

To specify single-line graphics

  1. In the Piping workspace, click Manage tab Style & Display panel Style Manager drop-down Piping System Definitions .
  2. In the left pane of Style Manager, expand Piping Objects.
  3. Expand Pipe System Definitions.
  4. Select a system.
  5. In the right pane, click the Single Line Graphics tab.

  6. Choose an action below:
    If you want to… then…
    display pipe and equipment as scaled 1-line

    select Show pipe and inline/anchored components as Single Line displays. Then for pipe sizes less than or equal to, enter an upper limit diameter.

    display pipe and equipment as graphical 1-line, not to scale, with equipment represented by schematic symbols

    select Display pipe and inline/anchored components as graphical 1-line. For pipe sizes less than or equal to, enter an upper limit diameter. Then for Inline/anchored MvPart plot length, enter a plot length.

  7. On the Single Line Graphics tab, clear Display pipe and inline/anchored components as single line displays and Display pipe and inline/anchored components as graphical 1-line.
  8. On the Single Line Graphics tab, select Display pipe and inline/anchored components as single line displays.
  9. For pipe sizes less than or equal to, enter an upper limit diameter.
  10. Select Display pipe and inline/anchored components as graphical 1-line.
  11. For pipe sizes less than or equal to, enter an upper limit diameter.
  12. Enter a plot length for inline/anchored MvParts.
  13. For Single Line Graphics Style (connector graphics), select a style.
    Tip: The blocks specified in the selected style will appear in the 1-line displays for the current system.