The RolledCurb subassembly inserts links for a rolled curb shape concrete curb-and-gutter with subbase.
The attachment point is at the curb lip or back of curb. This component can be attached to either the left or right side.
Parameter |
Description |
Type |
Default |
---|---|---|---|
Side | Specifies which side to place the subassembly | Left / Right | Right |
Top of Curb | Top of curb | Numeric, positive |
4.5 in 100 mm |
Back Height | Back height | Numeric, positive |
14.5 in 370 mm |
Bottom Width | Bottom width | Numeric, positive |
24 in 600 mm |
Front Height | Front height | Numeric, positive |
7 in 180 mm |
Width To Flowline | Width to flowline | Numeric, positive |
11.5 in 300 mm |
Flowline Height | Flowline height | Numeric, positive |
6.5 in 165 mm |
SubBase Depth | Subbase depth | Numeric, positive |
12 in 300 mm |
Attachment Point | Attachment point | Lip, BackCurb | Lip |
This section lists the parameters in this subassembly that can be mapped to one or more target objects. For more information, see To Specify Corridor Targets.
None.
None.
None.
The curb and gutter links are inserted based on the Input Parameter dimensions. All dimensions must be positive, non-zero values.
The subassembly builds the shape for a simple curb and gutter, with the attachment point either at (a) lip of the gutter, or (b) the back of the curb.
In layout mode, this subassembly displays the curb-and-gutter component based on the input parameters given.
The following table lists the point, link, and shape codes for this subassembly that have codes assigned to them. Point, link, or shape codes for this subassembly that do not have codes assigned are not included in this table.
Point, Link, or Shape |
Code |
Description |
---|---|---|
P1 | Flange | |
P6 | BackOfCurb | |
P7, P8 | CurbBottom | |
P9, P10 | SubBase | |
L1-L5 | Curb, Top | |
L8 | CurbBottom | |
L9 | Datum | |
S1 | Curb | |
S2 | SubBase |